“id” is the identification number of the metering device in the Nekta system.

“name” is the name of the device in the system.

“deviceID” is the key for connecting the meter to the Nekta software.

“active” is the status of the device, can have the values: 1 – the device is enabled, 0 – the device is disabled.

“protocol id” is the individual number of the meter driver in the Nekta system.

“gatewayID” is the key for connecting the gateway to the Nekta software.

“gateway id” is the gateway identification number in the Nekta system.

“inside_addr” is the network/internal address of the device. (for example: when connecting a pulse water meter with two inputs, the n1 or n2 input is indicated).

“port_addr” is the port address, the parameter is not used in the Nekta system.

“deviceTimezone” is the time zone set on the device in the Nekta system.

“interface_id” is the device connection type (for example: LoRaWAN, RS-485, Ethernet, Kt-IoT, Actility, etc.).

“creator_id” is the identification number of the user who created the device in the Nekta system.

“company_creator_id” is the identification number of the company where the device was created.

“model_class_id” is the identifier of the device class (for example: metering device or gateway).

“model_id” is the identification number of the device model (for example: VECTOR-300, Qalcosonic W1, Mercury 236 ART, etc.).

“device_type_id” is the identifier of the object type (for example: apartment, communal).

“device_group_id” is the identifier of the metering device group (for example: water, electricity, heat).

“report_period_update” is the polling period of the device in seconds.

“impulse_weight” is the weight of the pulse (for pulse metering devices).

“starting_value” is the starting value on the metering device (for pulse metering devices).

“transformation_ratio” is the transformation coefficient for electrical metering devices (not used).

“desk” is a data board (not used).

“last_active” is the last activity of the device in the Nekta system.

“created_at” is the date of creation of the metering device.

“updated_at” is the date of the last configuration change of the metering device.

“on_dashboard” is the device has been added to favorites (for example: true means added or if it is empty it is not).

“active_polling” is the presence of an active polling.

“IP” is the IP address of the device when establishing a connection via a TCP server.

“port” is the port through which the connection is made via a TCP server.

“modem_mode” is TCP connection type (For example: server or client)

“inside_addr” is the network/internal address of the modem.

“poll_fields” is polling parameters:

  • “current_tariff” is current energy;
  • “day_tariff” is energy at the beginning of the day;
  • “month_tariff” is energy at the beginning of the month;
  • “now_value” is instant values;
  • “power_profile” is power profile;

“selected_data” means service parameters:

  • “autoload_profile” means automatic collection of missed daily energy values;
  • “autoload_day” is automatic collection of missed power profiles;
  • “time_correction” means automatic time correction;
  • “autoload_journal” means automatic event log collection;
  • “autoload_PKE” means automatic collection of PCE;

“IMEI” is IMEI or device ID when connected via TCP client.

“type_water_meter” is the type of water read by the metering device:

  • “cold” means cold water;
  • “hot” means hot water;

“use3g” is the device is connected via the base station, which is connected via a 3G module.

“AppSKey” is the encryption key when using the ABP authorization type, 8 characters.

“DevAddr” is the address of the end device when using the ABP authorization type, 32 characters.

“NwkSKey” is the data integrity control key when using the ABP authorization type, 32 characters.

“freq_plan” is frequency plan of the device:

  • “RU868”
  • “Nekta”
  • “Smartiko”
  • “EU868”

“base_station” is priority base station.

“authorization_type” is the device authorization type (ABP, OTAA).

“AppKey” is the application key, 16 characters.

“DevEUI” is the device identification number, 32 characters.

“direction_water_meter” not used.

“software_7e1” is the data encoding is used via program mode 7e1.

“device_serial_number” is the serial number of the device attribute.

“device_password_user” is user password for the device.

“number_of_contract” is contract number/personal account.

“subscriber” is the consumer.

“device_personal_account” is the device’s personal account.

“1c_code_device” is the device code in 1C.

“company_name” is the company name.

“installation_location” is the installation location of the object.

“accounting_point_number” is the number of the accounting point.

Please note that the report is generated individually and the description of some fields may be missing. To clarify the information on the columns of interest in the report that are not specified in the article, it is necessary to send a request to the technical support service of the company Nekta by E-mail support@nekta.tech .